|
Kto jest w sklepie?
Sklep przegląda 6005 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
;
Wszystko w porządku.
Instrukcja czytelna i kompletna.
Dziękuję.
all right!
thank you.
;
Bardzo dobra instrukcja. Zawiera wszystko co potrzeba, polecam!
;
Instrukcja jest OK. Schematy czytelne, opisane niektóre procedury.
;
Instrukcja bardzo czytelna. zawiera co potrzeba. Polecam
;
...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Alignment and Adjustments
4-4 Other Adjustments
4-4-1 Screen Adjustment
1. Warm up the TV for at least 30 minutes. 2. Turn to the Video Mode (No Signal) using a remote-control. 3. Connect an oscilloscope to RK,GK,BK. 4. Adjust the VR (VR501, VR531, VR561) screen so that RK, GK, BK pulse is 20Vp-p each. (Turn the R,G,B VR screen fully counterclockwise in the area of each flyback line.)
4-4-3 Sub-Brightness Adjustment
1. Input a sub-brightness adjustment signal. (TOSHIBA PATTERN) 2. In the stand-by mode, press the remote-control keys in the following sequence : DISPLAY����U�MUTE �Power On 3. Select SBT by pressing the Volume +/- keys. 4. Adjust so that the 7th step on the right side of the screen is not seen (Use the Volume +/keys). 5. Press the Menu key to exit.
4-4-2 White Balance Adjustment
1. Select the �STANDARD� video mode. 2. Input 100% white pattern. 3. In the stand-by mode, press the remote-control keys in the following sequence: DISPLAY����U�MUTE �Power On 4. Warm up the TV for at least 30 minutes. 5. Input a 10-step signal. 6. R-cut off, B-cut off, and G-cut off by pressing the Volume +/- keys. 7. Adjust the low light with viewing the dark side of the screen. 8. Select R-drive, G-drive, and B-drive by pressing the Volume +/- keys. 9. Adjust the high light with viewing the light side of the screen. 10. If necessary, redo adjustments 6~9. 11. Press the Menu key to exit.
4-4-4 High Voltage (31KV) Check
PRECAUTION
1. Input a lion head pattern. 2. Select �STANDARD� video mode. 3. Warm up the TV for at least 10 minutes. 4. Use a 1000:1 probe.
ADJUSTMENT
1. Connect the (+) terminal of the 1000:1 probe to the high voltage distributor and the (-) terminal to GND (located on the deflection board). 2. Adjust VR471 (located on the deflection board) so that the digital meter indicates DC 31V ± 0.1V.
Samsung Electronics
4-7
|
|
|
> |
|