Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 30 (kliknij aby zobaczyć)
Alignment and Adjustments
4-5 Beam alignment Adjustments
1. Select the �DYNAMIC� video mode. 2. Warm up the set at least for 10 minutes. 3. Enter the Convergence mode by pressing the remote control buttons in the following sequence :
Mute
4. Set the Beam Alignment Adjustment CY to Zero magnetic field area.
(Creation of CPM Zero Magnet)
(Creation of the 2-pole/4-pole zero magnets)
5. Check the squarewave at the point where the focus is misaligned. 6. Press the button on the remote control during 3~5 sec and vibrating dot-pattern appears. 7. Adjust the Focus-pack VR for defocusing. 8. Mute the other patterns (R/B) other than G-PATTERN. (Use
G-FOCUS
/
TV
buttons on the remote control.)
CORE
Varying the 2-pole of VM (Varying G-Focus Pack) G-FOCUS CORE (Positioning the Core in the Center)
Varying the 4-pole of VM (When VM 2-Pole Adjustment is completed) (Adjust until the light around the core becomes a circle)
9. Adjust the 2, 4 polarities of VM-COIL as shown in figure below. 10. Adjust the G-Focus until any light around the core disappears. 11. Adjust G-Focus so that the surrounding flash can disappear from the spot. 12. After G-Focus adjustments are complete, adjust R-Focus as above procedures. 13. The B-CRT adjustments can be omitted because the variance of beam focus is small. (Only Vm-coil is mounted.) 14. Adjust the Focus-pack VR for fine focusing. 15. Press the mode. 16. Press the
S.STD
button on the remote control, and the mode changes to the Convergence Adjustment button on the remote control to return to normal viewing.