Audio * Please check and ensure the function of audio works well. (Volume, Treble, Bass, Mute) * If not, please return the unit to repair area. Screen Uniformity Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8) Test Pattern : Full White Pattern * Please check and ensure the unit is under the spec. * Please check and see if it� in normal condition.If not, please return the unit to s repair area. * The total numbers and distance of dead pixels should be complaint with the spec. Dead Pixel (Bright/Dark pixel) Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8) Test Pattern : Full Black Pattern and Full White Pattern (1) Bright Pixel : Test Pattern : Full Black Pattern -Please check and ensure that the unit cannot accept any bright pixel. (Suggested) -If not, please return the unit to repair area. (2) Dark Pixel : Test Pattern : Full White Pattern -Please check and ensure that the pixel number should be less than 6 pixels (Suggested) -If not, please return the unit to repair area.
-
-
4-6
Guide to Entering Factory Mode and Reset in OSD
How to enter Factory Mode:
1. 2. Must be with signal input. Hot key: press �ON/STANDBY� �VOL-� �VOL-� �MENU� sequentially to enter Fac tory Mode. (See the below pic)