10. Tighten the clamp screw.
5.9. CONVERGENCE 1. Apply a crosshatch pattern signal and set Contrast control to the maximum position. 2. Adjust Bright control to obtain a clear pattern. 3. Adjust Red and Blue line at center of the screen.
4. Adjust Red and Blue with Green line at center of the screen by rotating (RB)-G static convergence magnet. 5. Lock convergence magnets with silicone sealer. 6. Remove the DY wedges and slightly tilt the Deflection Yoke vertically.