UX-H33
2.2.6 Reattaching the Play/ Record & Clear head (See Fig.11~13) (1) Reattaching the head mount assembly. a) Change front of the direction cover of the head mount assembly to the left (Turn the head forward). b) Fit the bosses O', P', Q', U' and V' on the head mount assembly to the holes P and V, the slots O, U and Q of the mechanism sub assembly (See Fig.11 to 13). CAUTION: To remove the head mount assembly, turn the direction cover to the left to disengage the gear. If the gear can not be disengaged easily, push up the boss Q' slightly and raise the rear side of the head mounts slightly to return the direction lever to the reversing side. (2) Tighten the azimuth screw for reversing. (3) Reattach the spring from the back of the Play / Record & Clear head. (4) Connect the flexible wire to connector CN31 on the head amplifier & mechanism control board.