Table 4-4 8 Connect the terminated Oscilloscope with 75� to the Recording Output Connector on the Rear Panel. 8 Adjust VR18 so that the Border signal level becomes 700 ± 14 mV as shown in Fig. 4-5. 8 Adjust VR36 so that the Burst signal level becomes 300 ± 14 mV as shown in Fig. 4-5.
8 Confirm that the Sync signal level becomes 300 ± 30 mV 8 Press the Reset Button.
with 75� to the Multiscreen Output Connector on the Rear Panel.
8 Execute Program Number 044 Press the Camera
Selection Button/Preset Position Button 4, 4 and 16 sequentially, the Menu as shown in Table 4-5 will be displayed.
SELF CHECK
VR34 (C PHASE) Switch Board 8 Supply the Ramp signal to the Camera Input Connectors 1, PLAY-IN Connector and S-Video Connector of the Playback Input Connector on the Rear Panel. Note : The supplied signals to the Camera Input Connector 1 and S-Video Connector must be synchronized.
8 Connect the terminated Oscilloscope with 75� to the
044
H PHASE(M-2)
00-0F
0C
Table 4-5 8 Adjust VR20 so that the Border signal level becomes 700 ± 14 mV as shown in Fig. 4-6.