|
Kto jest w sklepie?
Sklep przegląda 5808 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
;
...instruction is ok.
...instrukcja jest ok.
Thanks/Dzięki
;
Documentation made available quickly and It is good quality. Thanks.
ADJUSTMENT -4/7
<FM Adjustment> Make the following preparations for FM adjustment. Preparations � Standard Signal Generator (S.S.G.) / Loop antenna / Oscilloscope / Millivoltmeter / Dummy resistance (6 �) 1) Connect the unit and measuring instruments as shown in the diagram below. 2) Connect the output of S.S.G. to the antenna input of the unit.
7. Tracking Adjustment Requirements: As instructed in preparations. � Adjustment point: L903 1) Set S.S.G. to FM; carrier of 87.5 MHz with 75 kHz modulation, and source at 1 kHz. 2) Tune the receiving frequency of the unit at FM 87.5 MHz. 3) While monitoring the waveform at 1 kHz through the oscilloscope, lower the output level of S.S.G. maximum (till a certain degree of noise is monitored). 4) Adjust L903 so that the millivoltmeter points maximum. 8. Separation Check Requirements: As instructed in preparations. 1) Set S.S.G. to FM; carrier of 98 MHz with 67.5 kHz modulation, source at 1 kHz, and output at 60 dBuV. 2) Switch S.S.G. to PILOT ON, and set PILOT at 7.5 kHz. 3) Tune the receiving frequency of the unit at FM 98 MHz. 4) Allow the output of S.S.G. only from Lch, and check that the difference between Lch and Rch is 25 dB or above. 5) Apply the above check to Rch. 9. Auto-Stop Check Requirements: As instructed in preparations. 1) Set S.S.G. to FM; carrier of 98 MHz with 75 kHz modulation, source at 1 kHz, and output at 10 ~ 35 dBuV or less. 2) Apply the tuning search function, and check that the unit automatically stops at FM 98 MHz.
-40-
|
|
|
> |
|