If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.
Positioning the Cooker
Caution: Some soft or badly fitted floor coverings can be damaged when the cooker is moved across their surface for cleaning. It is advisable to ensure that the floor covering in the area below the cooker is either securely fixed so as not to ruck up when the cooker is moved or, if preferred, removed.
Location
The cooker may be located in a kitchen, a kitchen/diner or bedsitting room but not in a bathroom, shower room or garage. For information regarding the fitting of flexible supply pipes, the highest temperature at the rear of this cooker which may come into contact with the supply pipe is 70°C above ambient. When the appliance has been installed there must be enough space fot the hotplate lid (when present) to open fully.
420 780
Installation
D C
115
1. Positioning the Appliance (Fig. 1)
E
Note A: The appliance is designed to be flush fitted with 2mm clearance at each side to allow for it to be pulled forward for cleaning etc. Note B: The hotplate side trims should be flush with the cabinets and must not be below. Adjustable levelling feet at the front and rear are provided on the base of the appliance. Adjustment is obtained by rotating in or out, the feet at the front or rear of the appliance from the underside of the appliance, with the drawer removed. A spirit level should be placed on a cake tray on one of the shelves to confirm that the appliance is correctly levelled. The levelling feet fitted to the appliance will achieve a height to hotplate trims of 900mm-0 + 10. Note C: If the appliance is fitted next to a side wall or cabinets above height of the hotplate trims, then a gap of 115 mm is required. Curtains must not be fitted immediately behind the cooker or within 115 mm of the sides of the cooker. Note D: Any wall cabinet or extractor must not be lower than 780mm above hotplate level. Note E: Wall cabinets may be fitted in line with the sides of the base units, providing that the lower edge of the wall cabinet is a minimum of 420mm above the worktop.
B
A
FO 1141
Dimensions are given in millimeters
Fig. 1
The appliance must be installed in accordance to the type X (standard EN 60335-2-6). Therefore the appliance cannot be installed beside furniture higher than the cooker worktop. This cooker must only be installed by qualified personnel, according to the manufacturer�s instructions and to the relevant British Standards.