Gruba instrukcja - poprostu wszystko co potrzreba - polecam .
Tekstowy podgląd strony 8 (kliknij aby zobaczyć)
Rear spacers
The plastic bag containing all relevant documentation also contains two rear wall spacers to be fitted into special slots on the back of the appliance. Fit the spacers into the slots, taking care to ensure that the arrow (A) is positioned as shown in the figure. Next, turn them through 45¡ (arrow in vertical position) until they lock into place.
45°
A
PR60
Door reversal
Unplug the appliance before all operations. To reverse the door, proceed as follows: 1. dismantle the lower hinge (3), pin (1) and the screw (2); 2. slide the door out from pin (D),unscrew the pin and reposition on the opposite side; 3. unscrew the left front foot and reposition on the opposite side; 4. unscrew the two screws which mask the holes for fixing the hinge from the left front side; 5. reassemble the door; 6. reassemble the lower hinge (turning it 180¡), the pin and the screw on the opposite side, as shown in the figure; 7. remove the handle, after having removed the screw cover and refit it on the opposite side. The holes that are not used must be mask with the plastic plugs removed.
D
D590
1 3 2
80° 1
2
Warning:
After having reversed the opening direction of the doors check that all the screws are properly tightened and that the magnetic seal adheres to the cabinet. If the ambient temperature is cold (i.e. in Wõnter), the gasket may not fit perfectly to the cabinet. In that case, wait for the natural fitting of the gasket or accelerate this process by heating up the part involved with a normal hairdrier.
D299
Fitting the door panel
(for models equipped with door frame) To fit the door panel, proceed as follows: ¥ remove the fixing screws and remove the frame side opposite the handle; ¥ loosen, without removing them, all remaining screws fixing the door frame; ¥ insert the panel from the side on which the frame has been removed and push it fully in; ¥ refit the frame side and tighten all the screws.
Note
The panel size should be 1-2 mm smaller than the door; the maximum permissible panel thickness is 4 mm.