6.8. Removal of B/Q-Module 1. Remove the upper case and A-P.C.Board block according to the steps 1 through 3 in the section 6.3. "Removal of A-P.C.Board". 2. Unscrew the 2 screws and remove the lamp unit terminal. 3. Unscrew the 3 screws. 4. While pressing to close the cap of the resinous stand, remove the B/Q-Module.
6.9. Removal of P-Module 1. Remove the upper case and A-P.C.Board block according to the steps 1 through 3 in the section 6.3. "Removal of A-P.C.Board". 2. Unscrew the 3 screws and remove the intake duct block. 3. Unscrew the 2 screws and remove the lamp unit terminal. 4. Unscrew the 2 screws and remove the power block (P-, B/QModules block).