jedyne do czego mogę mieć zastrzeżenie to jakość zdjęć zawartych w przesłanej instrukcji serwisowej ponieważ są fatalnej jakości, praktycznie nieczytelne. tak poza tym jestem zadowolony to jest to czego szukałem.
Instrukcja bardzo czytelna. zawiera co potrzeba. Polecam
Tekstowy podgląd strony 21 (kliknij aby zobaczyć)
� Adjustment method of VC PWM Duty (L) (mode number: 762) 1. Select the manual mode of the test mode, and set the mode number 762. (See page 14)
LCD display
� Adjustment method of VC PWM Duty (H) (mode number: 765) 1. Select the manual mode of the test mode, and set the mode number 765. (See page 14)
LCD display
762
VclPWM
765
VchPWM
2. Connect a digital voltmeter to the TP915 (VC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.5 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP915 (VC) TP5105 (GND)
2. Connect a digital voltmeter to the TP915 (VC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.5 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP915 (VC) TP5105 (GND)
3. Press the X key to write the adjusted value. � Adjustment method of VREM PWM Duty (H) (mode number: 763) 1. Select the manual mode of the test mode, and set the mode number 763. (See page 14)
LCD display
3. Press the X key to write the adjusted value. � Adjustment method of VREM PWM Duty (H) (mode number: 766) 1. Select the manual mode of the test mode, and set the mode number 766. (See page 14)
LCD display
763
VrhVcl
766
VrhVch
2. Connect a digital voltmeter to the TP914 (VR) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.75 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP914 (VC) TP5105 (GND)
2. Connect a digital voltmeter to the TP914 (VR) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.75 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP914 (VC) TP5105 (GND)
3. Press the X key to write the adjusted value. � Adjustment method of VREM PWM Duty (L) (mode number: 764) 1. Select the manual mode of the test mode, and set the mode number 764. (See page 14)
LCD display
3. Press the X key to write the adjusted value. � Adjustment method of VREM PWM Duty (L) (mode number: 767) 1. Select the manual mode of the test mode, and set the mode number 767. (See page 14)
LCD display
764
VrlVcl
767
VrlVch
2. Connect a digital voltmeter to the TP914 (VR) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.5 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP914 (VC) TP5105 (GND)
2. Connect a digital voltmeter to the TP914 (VR) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 2.5 ± 0.02 V. Proceed to the next step, if voltage is already adjusted.
digital voltmeter MAIN board TP914 (VC) TP5105 (GND)